RV Lithium Battery Upgrade Near Me

Coast to Coast RV Repair provides mobile lithium battery upgrade service on-site at your campground or driveway across Florida - certified technicians, same-week scheduling.

TL;DR

Coast to Coast RV Repair provides mobile lithium battery upgrade service on-site at your campground or driveway across Florida - certified technicians, same-week scheduling.

Certified technicians. $299 service call. Same-week scheduling. Call (866) 437-4848.

Coast to Coast RV Repair upgrades RV battery banks from lead-acid AGM to lithium iron phosphate (LiFePO4) at your campsite or driveway across Florida. A single 100Ah Battle Born GC3 or Renogy RBT100LFP12S-G1 swap starts at $1,250 installed with charger reconfiguration - most upgrades complete in 2 - 3 hours on a $299 mobile service call.

LiFePO4 vs AGM Battery Chemistry - What Changes When You Switch

Lithium iron phosphate batteries differ from AGM in four ways that matter to RV owners. First, usable capacity: AGM batteries are typically cycled to 50% depth of discharge to preserve calendar life, so a 100Ah AGM gives 50Ah usable. A 100Ah LiFePO4 from Battle Born or Renogy is safe to 80% DOD, yielding 80Ah usable - 60% more usable energy from the same nameplate. Second, cycle life: AGM rated at 300 cycles at 50% DOD versus 3,000 - 5,000 cycles at 80% DOD for quality LiFePO4 cells. Third, charge acceptance: AGM batteries taper to under 10A at 90% SOC, slowing the last 10% of charge significantly. LiFePO4 accepts full current up to 95% SOC, then tapers sharply - full recharge in a fraction of the time. Fourth, voltage sag: AGM voltage drops from 12.7V at full charge to 11.5V at 50% DOD under load, causing the inverter to see lower voltage and potentially shut down. LiFePO4 holds between 13.2V and 12.8V from 100% to 20% SOC - the inverter sees stable voltage and runs more efficiently.

BMS Compatibility and Charger Reconfiguration Requirements

Swapping AGM for LiFePO4 without reconfiguring the charger is the number one lithium upgrade mistake. Every quality LiFePO4 battery has an internal Battery Management System that protects cells from overcharge, overdischarge, excess current, and temperature extremes. A charger running at AGM absorption voltage (14.4V - 14.7V) into a lithium battery will not damage the cells in most cases because the BMS disconnects at 14.6V, but the cycling disconnect-reconnect as the charger over-targets and the BMS trips causes premature BMS MOSFET wear and erratic charge termination. Correct lithium charge profiles: absorption 14.2V, float 13.5V, equalize mode disabled. On Victron inverter/chargers this takes 5 minutes via VE.Configure. On Progressive Dynamics PD9100 series converters, the PD9105V Charge Wizard module adds a lithium-compatible 4-stage profile for $65.

Battery Bank Sizing - How Much Lithium Do You Actually Need

Over-sizing is common in lithium marketing and it adds unnecessary weight and cost. We size lithium banks from a logged consumption baseline, not from rule-of-thumb estimates. A Victron BMV-712 Smart battery monitor installed for 24 - 48 hours before the upgrade gives exact amp-hour consumption data. Typical Florida boondocking loads: a CPAP (ResMed AirSense 10 at 55W average) consumes 27Ah over 6 hours. A Dometic CRX-65 12V compressor fridge consumes 30 - 45Ah per day depending on ambient temperature. LED interior lighting consumes 10Ah over 5 hours of evening use. Total for a typical couple dry-camping: 75 - 100Ah per day. With a 200Ah LiFePO4 bank usable to 80% DOD (160Ah), that covers 1.5 - 2 nights before needing recharge.

Also see: Electrical & Solar Services

This page covers lithium battery upgrade specifically. For the full range of electrical & solar services we offer, visit our Electrical & Solar service overview.

Case Study: The two Interstate DCM0075 AGM batteries had been discharged below 50% depth of discharge on an estimated 180 out of 420 cycles - mostly during boondocking trips where the owner consistently ran loads until the inverter shut down. At 180 sub-50% DOD cycles on an AGM rated for 300 cycles at 50% DOD, the batteries were at end-of-life with internal sulfation reducing usable capacity to approximately 58% of nameplate.

RV: 2021 Winnebago Minnie Plus 27BHSS • Location: Highlands Hammock State Park Campground, Site 34 • City: Sebring

Symptom: The owner reported their two 12V Interstate DCM0075 AGM batteries lasting only 4 hours after a full charge before the Victron MultiPlus-II 12/2000/80 inverter's low-voltage alarm tripped at 11.8V, even though the batteries were only 14 months old. The morning coffee maker (900W) and CPAP (80W) were the primary overnight loads.

Diagnosis: Technician ran a Midtronics MDX-650P conductance test on both Interstate DCM0075 batteries. Battery 1 measured 285 CCA against a 400 CCA rating (71% - early degradation). Battery 2 measured 198 CCA against 400 CCA (49.5% - severe sulfation). Load test using a 50A discharge confirmed total bank capacity of 62Ah usable before reaching 11.8V - against a nameplate 150Ah (2x75Ah) usable at 50% DOD.

  1. Consumption Baseline: Connected the Victron BMV-712 for 24 hours to log actual overnight draw - measured 48Ah total from CPAP (80W x 6hr = 28Ah), Keurig (900W x 10min/day = 7Ah), LED lighting (3A x 4hr = 12Ah), and miscellaneous 12V loads (1Ah).
  2. AGM Removal: Disconnected and removed both Interstate DCM0075 batteries from the front pass-through bay - total weight 116 lbs for the pair.
  3. Lithium Bank Installation: Installed two Renogy RBT100LFP12S-G1 100Ah LiFePO4 batteries (50 lbs total for the pair) with internal Daly BMS rated for 100A continuous discharge. Wired in parallel using 2 AWG tinned copper cable with tinned lugs to maintain polarity and minimize voltage differential between cells.
  4. Converter Reconfiguration: Reprogrammed the existing Victron MultiPlus-II 12/2000/80 via VE.Configure 3 - changed absorption voltage from 14.4V to 14.2V, float voltage from 13.6V to 13.5V, disabled equalization mode (destructive to lithium), and set charge current to 80A (within the Renogy BMS 100A charge limit).
  5. Shore Power Charge Profile Verification: Confirmed the Winnebago's OEM Progressive Dynamics PD9130 30A converter was also reconfigured to lithium profile (14.2V/13.5V) using the PD9105V Charge Wizard plug-in module.
  6. Capacity Verification: Discharged the new lithium bank to 10% SOC using a 50A load then recharged to 100% - confirmed 182Ah total capacity per BMV-712 log, matching nameplate specification for the parallel 200Ah bank.
  7. Runtime Test: Ran CPAP (80W) and lights (36W) for a simulated 8-hour night - bank reached 71% SOC at end of test, with 58Ah consumed and 142Ah remaining.

Outcome: The owner's 4-night boondocking trips now end with the battery bank at 35 - 40% SOC instead of triggering inverter shutdowns by midnight. They added a 200W Renogy solar panel to replenish daytime draw from the slide-out and water pump.

Time on-site: 2 hours 50 minutes • Total cost: $299 service call + $890 two Renogy RBT100LFP12S-G1 batteries + $65 PD9105V Charge Wizard + $285 labor • Dealer alternative: Winnebago dealer in Orlando quoted $1,850 installed for two Battle Born 100Ah batteries plus a $385 diagnostic fee and 5-day drop-off requirement.

“The old batteries lasted 14 months and were garbage by the end. These lithium ones weigh half as much and I woke up with 70% battery left after running the CPAP all night.”

Lithium Battery Brand Comparison - 100Ah 12V Units

Brand/ModelUsable Capacity (80% DOD)Cycle Life (80% DOD)Max Charge CurrentBMS Low-Temp CutoffWeightPrice (Installed)
Battle Born BBgc3 100Ah80Ah3,000+ cycles50A25F (-4C)31 lbs$1,350 - $1,550
Renogy RBT100LFP12S-G180Ah4,000+ cycles100A32F (0C)24 lbs$1,150 - $1,350
Lithionics NeverDie 100Ah80Ah3,500+ cycles100A23F (-5C)29 lbs$1,550 - $1,850
Lion Energy UT 1300 105Ah84Ah2,000+ cycles80A32F (0C)27 lbs$1,250 - $1,450
Interstate DCM0100 AGM (comparison)50Ah (50% DOD)300 cycles (50% DOD)20A typicalNone63 lbs$285 - $385

Signs You Need Lithium Battery Upgrade

  • Log your actual daily amp-hour consumption with a Victron BMV-712 or Victron SmartShunt 500A for 48 hours before sizing a lithium bank - skip this step and you will likely over-buy capacity
  • Confirm every charging source - converter, inverter/charger, and solar MPPT - has been reconfigured to lithium profile (14.2V absorption, 13.5V float, equalize disabled) before putting the batteries under charge
  • Verify the battery compartment ventilation requirements change with lithium - LiFePO4 does not off-gas hydrogen like flooded lead-acid, but the space must still accommodate the BMS heat output at high charge current
  • Check that your battery cable gauge and terminal hardware is rated for the new lithium bank's higher charge acceptance
  • Test the BMS low-temperature cutoff before a cold-weather trip by cooling one battery to 32F and confirming charge current stops while discharge continues
  • If installing multiple lithium batteries in parallel, use identical cables of the same gauge and length to each battery

Lithium Battery Upgrade - Pricing

Typical price range: $895 - $4,200

All calls start with a $299 service-call fee that covers the technician's trip to your location and the first hour of diagnosis. That $299 applies toward any repair you authorize - it is not an additional charge on top of the repair. Pricing shown is a national average range; your exact quote is provided in writing on-site before any work begins.

FAQ

Lithium Battery Upgrade - Common Questions

Straight answers from our lithium battery upgrade service call log.

Can I mix one lithium battery with my existing AGM batteries?

No. Lithium and AGM have incompatible voltage curves. A lithium battery holds 13.2V at 80% charge while an AGM holds 12.5V at 80% charge. In parallel, the lithium will continuously dump current into the AGM bank trying to equalize voltages, overworking its BMS and overcharging the AGMs. Always replace the entire bank with the same chemistry.

My Battle Born batteries have a 10-year warranty - does that cover installation labor?

Battle Born's warranty covers cell and BMS defects in manufacturing for 10 years. It does not cover labor. If a battery fails under warranty within the first 2 years, they typically replace it pre-paid. After year 2, you ship the battery back at your cost.

Will lithium batteries work with my existing generator's battery charger?

Most Onan 5500 and Cummins QD 5500 built-in generator charger circuits output a 13.5V - 13.8V float voltage, which is within the safe range for LiFePO4 but too low to fully charge the bank. The generator charger tops the bank out at roughly 85% SOC. This is acceptable for occasional use but means you should not rely on the generator charger alone.

How long does a 200Ah lithium bank take to charge from 20% SOC to full?

At 100A charge current, 160Ah of recharge takes 1.6 hours. In practice with a 30A Progressive Dynamics converter delivering 30A charge current, the same recharge takes 5.3 hours. A 400W solar array in full Florida sun adds 30A of solar charge current in parallel, bringing the combined charge rate to 60A and the recharge time to 2.7 hours.

Do I need to upgrade my shore power cord or converter when going lithium?

Usually the converter, sometimes the cable, rarely the shore cord. The converter charge profile must be reconfigured or replaced. If the converter is a WFCO WF-8935 or older Parallax 7300, we recommend replacement with a Progressive Dynamics PD9160AL because recalibrating the WFCO to lithium voltage is unreliable in Florida heat.